l-Buthionine Sulfoximine Detection and Quantification in Polyurea Dendrimer Nanoformulations. ↗
Mota P, Pires RF, Serpa J, Bonifácio VDB.
Vad undersöktes?
- Hur undersöktes det?
- In this study, l-BSO was encapsulated in a folate-targeted generation four polyurea dendrimer (PUREG4-FA2) and its release profile was followed for 24 h at pH 7.4 and 37 °C.
- Vilka undersöktes?
- Ingen uppgift i sammanställningen
- Vilken ämnesform?
- l-Buthionine-(S,R)-sulfoximine (l-BSO)
- Vilken mängd användes?
- standard solutions of l-BSO were prepared in the concentration range of 0.1–150 µM in PBS
- Hur länge pågick studien?
- 24 h
Studieuppgifterna återges som originalcitat. Uppgifter som saknas här kan finnas i originalutdraget.
Vad kom studien fram till?
Författarna rapporterar en metod för att detektera och kvantifiera l-buthionine-(S,R)-sulfoximine efter derivatisering med katekol och natriumperiodat. Derivatets absorbans mättes vid 503 nm; kalibreringskurvan omfattade 0.1–150 µM och hade R2 = 0.997. De följde också frisättning av l-BSO från en folatmålstyrd polyureadendrimer vid pH 7.4; den rapporterade frisättningen var omkring 60 % efter 1 h och 90 % efter 24 h. Detta är en analys- och formuleringstudie, inte en klinisk prövning av behandlingseffekt.
Vad behöver resultatet vägas mot?
Underlaget omfattar endast utvalda artikelstycken; någon samlad bedömning kan inte göras. Styckena beskriver en analysmetod och frisättning från en dendrimerformulering, inte kliniska utfall.
Läs de originalstycken som sammanställningen bygger på
Abstractl-Buthionine sulfoximine (l-BSO) is an adjuvant drug that is reported to increase the sensitivity of cancer cells to neoplastic agents. Dendrimers are exceptional drug delivery systems and l-BSO nanoformulations are envisaged as potential chemotherapeutics. The absorption of l-BSO at a low wavelength limits its detection by conventional analytical tools. A simple and sensitive method for l-BSO detection and quantification is now reported. In this study, l-BSO was encapsulated in a folate-targeted generation four polyurea dendrimer (PUREG4-FA2) and its release profile was followed for 24 h at pH 7.4 and 37 °C. The protocol uses in situ l-BSO derivatization, by the formation of a catechol-derived orto-quinone, followed by visible detection of the derivative at 503 nm. The structure of the studied l-BSO derivative was assessed by NMR spectroscopy.
2.1. l-BSO Encapsulation and Release Studiesshows the l-BSO release profile from a l-BSO@PUREG4-FA2 nanoformulation at pH 7.4. The release was followed for 24 h and the results indicate a burst release in the first hours, as expected in this type of delivery system [,]. After 1 h, around 60% of the loaded drug was released to the medium, reaching a plateau after 3 h. After 24 h, 90% of l-BSO was released, meaning that only a residual amount of l-BSO was trapped inside the PUREG4-FA2 dendrimer during this period of time. The quantification of BSO released from the PUREG4-FA2 dendrimer was determined using a calibration curve, obtained from an assay under the same experimental conditions (see ). In more acidic media, a faster release is expected.
3.1. Reagents and Materialsl-Buthionine-(S,R)-sulfoximine (l-BSO) (≥97% purity) was obtained from Sigma-Aldrich. All chemicals and solvents were used as received without further purification. Polyurea (PURE) dendrimer generation four (PUREG4) was synthesized following our reported supercritical-assisted polymerization [].
3.5. Quantification of BSO by UV-Vis SpectroscopyUsing a modified protocol [], l-BSO was derivatized in order to be detected by UV-Vis spectroscopy. l-BSO quantification was performed by adding to the samples 300 µL of catechol 2.25 mM in PBS, followed by 300 µL of sodium periodate 6.75 mM in PBS. After 60 sec, the absorption of the l-BSO derivative (503 nm) was measured in a PerkinElmer Lambda 25 UV-Vis Spectrometer with a slit width of 5 nm at a scan rate of 240 nm min−1 at 25 °C. For the calibration curve, standard solutions of l-BSO were prepared in the concentration range of 0.1–150 µM in PBS and processed using the same protocol. A good correlation coefficient (R2 = 0.997) was obtained (see ).